
Equipment
Outdoor unit
HEIKO
Klimatyzacja
Moc klimatyzatora
Klimatyzatory 5 kW
Outdoor units MULTI SPLIT
Outdoor units MULTI SPLIT
The HEIKO outdoor unit for the MULTI SPLIT system is a key component of a modern air conditioning installation in a house, apartment, or commercial building. The inverter technology and environmentally friendly R32 refrigerant ensure high energy efficiency, stable operation, and optimal power adjustment to demand. The MULTI SPLIT solution allows you to connect several indoor units to one outdoor unit, reducing the number of devices on the facade and improving the aesthetics of the building, without compromising on performance and comfort.
Specifications
| OUTDOOR UNIT | M2T050-D2 | M2T050-D3 | M3T065-D2 | M5T100-D1 | ||
| Electrical rating | Power supply | Ph/V/Hz | 1/220-240/50 | 1/220-240/50 | 1/220-240/50/60 | 1/220-240/50/60 |
| Performance | Airflow | m3/h | 2900 | 2900 | 3000 | 4200 |
| Sound Power Level | dB(A) | 63 | 63 | 63 | 71 | |
| Sound pressure level | dB(A) | 53 | 53 | 54 | 55 | |
| Installation | Net dimensions (W/H/D) | mm | 800/280/550 | 800/280/553 | 800/300/550 | 920/372/760 |
| Gross dimensions (W/H/D) | mm | 902/375/607 | 902/375/607 | 940/438/605 | 1036/478/820 | |
| Weight, net/gross | kg | 36/39 | 35/38 | 37,5/40,5 | 66/71 | |
| Compressor type | Rotary | Twin rotary | Twin rotary | Twin rotary | ||
| Refrigerant | R32 | R32 | R32 | R32 | ||
| GWP | 675 | 675 | 675 | 675 | ||
| Liquid pipe diameter | mm | 2×6.35 | 2×6.35 | 3×6.35 | 5×6.35 | |
| Gas pipe diameter | mm | 2×9.52 | 2×9.52 | 3×9.52 | 3×9.52+2×12.7 | |
| Total piping length (max) | m | 30 | 50 | 60 | 80 | |
| Max level difference | m | 15 | 15 | 15 | 25 | |
| Refrigerant amount | kg | 1.1 | 1.05 | 1.1 | 2.4 | |
| Total piping length without extra charge | m | 20 | 20 | 30 | 40 | |
| Extra refrigerant charge per metre of piping | g/m | 20 | 15 | 20 | 20 | |
| Operating conditions (outdoor) | Cooling (min – max) | °C | -10 ~ 46 | -20 ~ 50 | -15 ~ 53 | -10 ~ 46 |
| Heating (min – max) | °C | -15 ~ 24 | -25 ~ 24 | -15 ~ 24 | -15 ~ 24 | |
| OUTDOOR UNIT | M2T050-D2 | M2T050-D3 | M3T065-D2 | M5T100-D1 | ||
| MAX NO. OF INDOOR UNITS PER OUTDOOR UNIT | 2 | 2 | 3 | 5 | ||
| INDOOR UNITS | 2*JS025 | 2*JS035 | 3*JS025 | 2*JS025+JS035+JS050 | ||
| Rated value | Cooling capacity | kW (nom. (min.-max.) | 5 (1.3-6.0) | 4.8 (1.8-5.5) | 6.3 (1.1-6.8) | 9.5 |
| Heating capacity | kW (nom. (min.-max.) | 5.7 (1.8-6.6) | 5.2 (1.5-6.3) | 6.6 (1.8-6.8) | 10.0 | |
| Input power for cooling | kW nom. | 1.45 (0.35-2.55) | 1.49 (0.15-2.05) | 1.95 (0.55-2.7) | 3.4 | |
| Input power for heating | kW nom. | 1.4 (0.55-2.8) | 1.35 (0.38-2.24) | 1.78 (0.55-2.5) | 2.8 | |
| EER/COP | 3.5/3.7 | 3.23/3.71 | 3.23/3.71 | 2.7/3.2 | ||
| Seasonal value | SEER/SCOP | 6.1/4.0 | 6.5/4.0 | 7.0/4.0 | 6.2/3.8 | |
| Energy rating (cooling/heating) | A++/A+ | A++/A+ | A++/A+ | A++/A | ||
| Annual energy consumption (cooling) | kWh | 269 | 258 | 315 | 537 | |
| Annual energy consumption (heating) | kWh | 1645 | 1470 | 1889 | 2889 | |
Downloads
Product cards - Outdoor units
Declaration of conformity - SPLIT and MULTI SPLIT air conditioners
Knowledge base
30.06.2026
Blog
How to Control Your Home’s Indoor Climate? HVAC Integration and Wi-Fi Connectivity
Discover how HEIKO integrates heat pumps, air conditioning and heat recovery ventilation through smart mobile apps for year-round indoor comfort and energy-efficient operation.
Go to entry
22.06.2026
BlogGuide
Split or Multi Split – Which Air Conditioning System Is Best for Your Apartment?
Split or Multi Split? Learn the key differences, compare installation options, and discover which HEIKO air conditioning system best suits your home.
Go to entry
20.06.2026
BlogGuide
Enthalpy Heat Recovery Ventilation – How to Recover Heat and Moisture in Your Home
Learn how HEIKO HCP enthalpy heat recovery units recover both heat and moisture to improve indoor comfort, support air conditioning, and increase energy efficiency throughout the year.
Go to entry