Heat Pump Day 2026 – Discover HEIKO THERMAL and THERMAL Plus Heat Pumps
Date of publication
Category

Devices from the article

On 21 October, we celebrate Heat Pump Day, an initiative promoting modern heating technologies and raising awareness of their benefits. It is an excellent opportunity to discover HEIKO THERMAL CO + DHW and THERMAL Plus CO + DHW heat pumps. These monobloc air-to-water heat pumps use energy from outdoor air to heat buildings, provide space cooling and produce domestic hot water (DHW).

Both product ranges are available in 6, 9, 12, 15 and 19 kW models. This makes it possible to select a unit according to a building’s heating demand and the type of heating system installed. Discover how HEIKO technologies translate into everyday comfort and energy efficiency.

 

HEIKO Heat Pumps – Heating, Cooling and Domestic Hot Water in One System

A heat pump can meet several everyday needs through a single system. In winter, it supplies heat to the heating system, while in summer, it can also provide space cooling when the installation is configured accordingly. It can also produce domestic hot water.

By using energy from outdoor air, a heat pump reduces reliance on fuels burned on-site. Combining a heat pump with a photovoltaic (PV) system also makes it possible to use some of the electricity generated on-site, reducing the amount of electricity purchased from the grid.

HEIKO heat pumps use R32 refrigerant, which has a lower global warming potential than many refrigerants used in older systems while maintaining high performance.

 

Heat Pump COP – What Does It Mean in Practice?

One of the key parameters to consider when choosing a heat pump is COP (Coefficient of Performance). It indicates the ratio of heat output to electrical energy input under specific operating conditions.

What does this mean in practice? A COP of 4 means that the heat pump delivers 4 kWh of heat for every 1 kWh of electricity consumed under the stated test conditions. This is possible because the unit also transfers thermal energy from the surrounding air.

The COP values for HEIKO THERMAL and THERMAL Plus models are presented below.

Heat pump model COP at 2°C outdoor temperature, water 30/35°C COP at 7°C outdoor temperature, water 47/55°C
THERMAL / THERMAL Plus 6 3.80 4.61
THERMAL / THERMAL Plus 9 3.87 4.38
THERMAL / THERMAL Plus 12 3.90 4.30
THERMAL / THERMAL Plus 15 4.00 5.00
THERMAL / THERMAL Plus 19 4.47 4.47

The values refer to two different test points specified in the product documentation. COP is not constant throughout the heating season, and results should not be compared without taking the test conditions into account.

The overall efficiency of a heat pump system also depends on the building’s energy performance, the heating system’s flow temperature and the way the unit is operated.

 

Inverter Technology – Output Adjusted to Actual Demand

HEIKO heat pumps feature inverter technology, which enables the compressor to adjust its output smoothly according to the current heating demand. Instead of constantly running at full capacity, the unit can adapt its performance to the prevailing conditions.

This helps maintain a more stable indoor temperature, reduces frequent compressor start-up and shutdown cycles, and supports more efficient energy use. Modulating operation can also help reduce operating noise, improving everyday comfort.

 

Weather Compensation – Heating Adapted to Outdoor Conditions

HEIKO THERMAL heat pumps can automatically adjust their operating parameters according to the outdoor temperature using a heating curve. When the weather becomes warmer, the system can lower the heating water temperature; when temperatures drop, it can increase it accordingly.

This reduces the need for manual adjustments and helps maintain comfortable indoor conditions as the weather changes. Matching the flow temperature to actual demand can also support efficient heat pump operation, particularly in low-temperature heating systems.

 

Two Heating Circuits – Greater Flexibility in System Design

HEIKO THERMAL Plus heat pumps support two heating circuits, allowing separate temperature settings for different heat emitters, such as radiators and underfloor heating.

This is particularly useful in buildings with heating systems that require different flow temperatures. Designers gain greater flexibility when planning the installation, while users benefit from heating settings better suited to the needs of different areas of the building.

 

HEIKO THERMAL or THERMAL Plus? Choose the Right Solution for Your Project

HEIKO THERMAL CO + DHW is a monobloc heat pump with a hydraulic module, designed for space heating, cooling and domestic hot water production. The range includes 6, 9, 12, 15 and 19 kW models, making it easier to select a unit according to the building’s heating demand.

HEIKO THERMAL Plus CO + DHW extends these capabilities with an integrated 250-litre domestic hot water tank. Its ALL IN ONE design reduces the need for separate space for an additional cylinder, while support for two heating circuits offers greater flexibility when designing the system.

Both ranges achieve seasonal space-heating energy efficiency classes of A+++ at a 35°C flow temperature and A++ at 55°C under average climate conditions. They can operate in heating mode at outdoor temperatures down to -25°C and produce hot water at temperatures of up to 55°C. These capabilities provide useful flexibility when designing a system for changing outdoor conditions.

 

Heat Pump Day – Discover the Possibilities of HEIKO

Heat Pump Day is a great opportunity to learn more about modern heating technologies and make informed decisions when choosing a heating system. Energy efficiency, inverter technology, weather compensation and the ability to adapt the system to different heat emitters are all important factors to consider when planning an investment.

Discover HEIKO THERMAL and THERMAL Plus heat pumps and find the solution that best meets your building’s requirements.